Technical resources

Technical guides for better battery and energy-storage decisions

Use practical sizing, architecture, safety, chemistry, and RFQ guidance to turn an early requirement into a more complete project brief.

Buyer knowledge center

Ten practical guides for project planning

Each guide focuses on a decision buyers need to make before comparing models, requesting documents, or asking for a quotation.

selection guide

C&I BESS Sizing Guide

A defensible C&I BESS size comes from interval load data, a ranked operating objective, power constraints, required duration, and a model of usable—not just nameplate—energy.

Read guide →
selection guide

Home Battery Sizing

Home-battery sizing starts with a critical-load schedule, power and surge requirements, daily energy, desired autonomy, solar production, and the inverter's supported battery configuration.

Read guide →
technology guide

Air vs Liquid Cooling

Air and liquid cooling are system-level choices. Compare heat density, temperature uniformity, ambient conditions, parasitic demand, acoustic limits, maintenance, fault response, and site layout—not capacity alone.

Read guide →
buyer guide

BESS Safety Review

A BESS safety review should connect cell and module behavior to electrical protection, BMS controls, thermal management, enclosure, fire strategy, emergency response, site layout, installation, and operating procedures.

Read guide →
buyer guide

Solar Battery Decision Guide

A solar battery is worth evaluating when it supports a defined objective that can be modeled from interval loads, solar production, outage needs, export limits, tariffs, and operating constraints.

Read guide →
selection guide

Home Battery Formats

Rack, stacked, and wall-mounted batteries mainly differ in mechanical format, expansion method, service access, footprint, cable routing, and integration. Energy needs and inverter compatibility remain the first filters.

Read guide →
technology guide

How VRLA AGM Works

A VRLA AGM battery immobilizes electrolyte in a glass-mat separator and is designed for gas recombination under controlled charging, but it still requires correct voltage, temperature, protection, ventilation, inspection, and replacement planning.

Read guide →
selection guide

LiFePO4 vs VRLA

Choose LiFePO4 or VRLA from the duty cycle, power, usable energy, charging, temperature, weight, space, maintenance, system integration, replacement plan, and total project cost—not a chemistry slogan.

Read guide →
buyer guide

BESS RFQ Checklist

A useful BESS RFQ states the operating objective, site data, power, usable energy, duration, electrical interface, environment, safety requirements, scope split, documents, and acceptance criteria.

Read guide →
technology guide

Nominal vs Usable Energy

Nominal energy is a nameplate quantity; usable energy is the portion permitted by the proposed operating window and system limits. Delivered AC energy can be lower again after conversion and auxiliary losses.

Read guide →

Turn the guide into a project brief

Use the checklist and then send the actual load, application, site, interface, destination, and schedule for review.