What duration and dispatch profile must the system support?
Include this information in the RFQ so a reviewer can compare the right architecture and operating limits.
Response target: within 12 hours for project inquiries
energy storage
Integrated high-energy storage formats for larger renewable, microgrid, and site-level projects.

Containerized projects require coordinated electrical, thermal, protection, control, fire, civil, and grid-interface design.
Include this information in the RFQ so a reviewer can compare the right architecture and operating limits.
Include this information in the RFQ so a reviewer can compare the right architecture and operating limits.
Include this information in the RFQ so a reviewer can compare the right architecture and operating limits.
A battery-container energy rating does not define the complete AC system. For PowerFac-5M, separate the DC battery platform from the proposed PCS, transformer, switchgear, EMS, protection and site works. Compare quotations against the same equipment and service boundary rather than assuming every item is included.
Check delivery access, lifting and foundation requirements, service space, cable routes, fire and acoustic studies, and the electrical interfaces. Include installation, commissioning and acceptance responsibilities in the quotation. Agree the factory and site records needed to demonstrate the quoted configuration and hand over the system.
Use one row per requirement and test stage. This is an evidence-recording template; test methods, acceptance limits and approval authority must be agreed by the project parties. A model name alone does not identify the tested configuration. Use role names and non-personal evidence references.
Before testing, leave results and evidence blank and retain a pending status. Mark deviation and closure fields as inapplicable only when that is established. An empty closure field does not close an open item. Preserve unknown conditions rather than pre-filling limits or a pass result.
Blank means unavailable, not supplied or not applicable; it never means zero or pass. Enter zero only when the source explicitly records zero. Do not include names, email addresses, phone numbers, driver identities or payment data.
| CSV field | What to record |
|---|---|
| requirement_id | Identifier linking this row to the project requirement. |
| requirement_description | Requirement or operating duty under review. |
| acceptance_stage_fat_or_sat | Factory acceptance testing (FAT) or site acceptance testing (SAT). |
| configuration_revision_and_settings_reference | Reference tested equipment, hardware, software, firmware and approved settings. |
| measurement_point_and_boundary | Identify the measurement point and included equipment and loads. |
| test_method | Reference the agreed procedure and relevant test conditions. |
| agreed_acceptance_criteria | Project parties' agreed acceptance conditions or limits. |
| test_scope_and_limitations | Tested combinations, simulated interfaces, exclusions and deferred checks. |
| evidence_file_reference | Reference the report, measurement export or supporting evidence. |
| observed_result_with_units | Measured result or observed behavior, with units where applicable. |
| deviation_or_open_item | Deviation, unresolved item or untested requirement. |
| closure_owner_role | Project role responsible for resolving an open item. |
| closure_status | Current state without implying unverified acceptance. |
| closure_evidence_reference | Evidence supporting closure or a retest decision. |
| acceptance_authority_role | Project role authorized to accept the stated scope. |
Published products
Use these ratings to create a shortlist. Final configuration still depends on the project, operating conditions, and destination requirements.
Start with the published ratings below, then open the model page for operating conditions and supply scope. Nominal battery energy is not a usable AC energy or runtime guarantee. A missing power value must be confirmed with the proposed PCS and system configuration.
| Model | Published rated power | Nominal battery energy | Cooling | Next step |
|---|---|---|---|---|
| 500 kW / 1075.2 kWh ESS | 500 kW | 1075.2 kWh | Confirm with selected configuration | Request model documents |
| PowerFac-5M | Confirm with system configuration | 5,016 kWh | Liquid cooling | Request model documents |
Compare a DC battery container with a complete AC system →
Plan the site, delivery access and system scope for PowerFac-5M →

A 500 kW / 1075.2 kWh containerized system configuration with a stated two-hour duration and IP54 enclosure rating.

A 5,016 kWh liquid-cooled DC-side battery platform for utility-scale renewable, grid-support, and large microgrid projects.
Related families
Project-configured battery systems for commercial, industrial, residential, and containerized storage applications.
Compare family →Battery cabinets and integrated systems for site energy management, renewable integration, and resilience planning.
Compare family →Product options for your application and installation conditions.